disque dur trés récent en format 2.5 500Go 5200T/mn  de marque seagate (type pour portable)
choisi pour la faible rotation et faible consommation pour archiver , grosse erreur de ma part roll


smartctl --all /dev/sdc
 


retour


smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Laptop Thin HDD
Device Model:     ST500LT012-1DG142
Serial Number:    W3PCM3AP
LU WWN Device Id: 5 000c50 07d75a8ec
Firmware Version: 0001SDM1
User Capacity:    500 107 862 016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Sat Feb 27 13:38:52 2016 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
          was completed without error.
          Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
          without error or no self-test has ever
          been run.
Total time to complete Offline
data collection:    (    0) seconds.
Offline data collection
capabilities:        (0x7b) SMART execute Offline immediate.
          Auto Offline data collection on/off support.
          Suspend Offline collection upon new
          command.
          Offline surface scan supported.
          Self-test supported.
          Conveyance Self-test supported.
          Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
          power-saving mode.
          Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
          General Purpose Logging supported.
Short self-test routine
recommended polling time:    (   1) minutes.
Extended self-test routine
recommended polling time:    ( 103) minutes.
Conveyance self-test routine
recommended polling time:    (   2) minutes.
SCT capabilities:          (0x1035) SCT Status supported.
          SCT Feature Control supported.
          SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   087   086   006    Pre-fail  Always       -       2629952
  3 Spin_Up_Time            0x0003   099   099   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       14
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       48
  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always       -       51539613448
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       627 (145 227 0)
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       14
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   092   092   000    Old_age   Always       -       8
188 Command_Timeout         0x0032   100   094   000    Old_age   Always       -       25770524683
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   072   055   045    Old_age   Always       -       28 (Min/Max 26/28)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       226
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       0
193 Load_Cycle_Count        0x0032   099   099   000    Old_age   Always       -       3904
194 Temperature_Celsius     0x0022   028   045   000    Old_age   Always       -       28 (0 24 0 0 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   100   000    Old_age   Offline      -       13 (34 157 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       679425773
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       1010371
254 Free_Fall_Sensor        0x0032   100   100   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
 


déja 48 secteur remplacé (627h d'utilisation) , sur un pc fixe , j imagine sur un portable qui voyage  sad
déçu par seagate ( IDE et SATA )
dans les bon élèves sur mes vieux disques Hitachi , Western Digital , Samsung , mauvais IBM , Maxtor , Seagate
je vais certainement  acheter un WD black (le red est presque plein hmm )
Je me pose la question si sur debian il n'est pas possible de mettre le disque en veille (proprement) si il n'est pas utilisé roll
le WD red pro est fait pour du NAS et il me semble que celui ci se met en veille si aucune activité

#52 27-02-2016 14:27:31

raleur
Membre
Inscription : 03-10-2014

Re : Vérifier vieux disque dur

On peut voir que ce disque est au "format avancé" (Advanced Format) 512e, c'est-à-dire qu'il a des secteurs logiques adressables de 512 octets, la taille traditionnelle, mais des secteurs physiques de 4096 octets. Les secteurs logiques sont donc regroupés par 8 dans des secteurs physiques. Je soupçonne que le nombre de secteurs réalloués affiché soit en fait le nombre de secteurs logiques, et qu'il faille le diviser par 8 pour obtenir le nombre de secteurs physiques. Il n'y aurait donc en fait que 6 secteurs physiques réalloués. En tout cas cela représente moins de 1% de la réserve puisque la valeur normalisée de l'attribut reallocated est encore à sa valeur initiale 100. L'important reste que les attributs pending et uncorrectable sont à 0, signe qu'aucune donnée n'a été perdue.

En tout cas il est intéressant d'activer la surveillance de ce disque par smartd afin de suivre l'évolution du nombre de secteurs réalloués au cours du temps.

Il vaut mieux montrer que raconter.

Hors ligne

#53 27-02-2016 17:02:59

anonyme
Invité

Re : Vérifier vieux disque dur

je te poste le retour de smart de la derniere machine que j'ai monté en skylake
sdc un disque 2.5 identique a celui du post au dessus (sata3 2.5 5200T/mn  seagate)
sdb est un ssd en sata3
sda est un ssd M2 dans un logement sur la carte mere (PCIe )
ps: pour surveiller sdb , mais pour les 2 ssd je sais pas ce que ça va donner le résultat est surprenant

le dd sata3 sdc


smartctl -a /dev/sdc
 


retour


smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.3.0-1-amd64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Laptop Thin HDD
Device Model:     ST500LT012-1DG142
Serial Number:    S3PDS65T
LU WWN Device Id: 5 000c50 0759419e3
Firmware Version: 0001SDM1
User Capacity:    500 107 862 016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sat Feb 27 16:07:52 2016 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
          was completed without error.
          Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
          without error or no self-test has ever
          been run.
Total time to complete Offline
data collection:    (    0) seconds.
Offline data collection
capabilities:        (0x7b) SMART execute Offline immediate.
          Auto Offline data collection on/off support.
          Suspend Offline collection upon new
          command.
          Offline surface scan supported.
          Self-test supported.
          Conveyance Self-test supported.
          Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
          power-saving mode.
          Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
          General Purpose Logging supported.
Short self-test routine
recommended polling time:    (   1) minutes.
Extended self-test routine
recommended polling time:    ( 101) minutes.
Conveyance self-test routine
recommended polling time:    (   2) minutes.
SCT capabilities:          (0x1035) SCT Status supported.
          SCT Feature Control supported.
          SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   108   100   006    Pre-fail  Always       -       19366536
  3 Spin_Up_Time            0x0003   099   099   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       47
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always       -       422438
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       1383 (56 200 0)
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       46
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   069   055   045    Old_age   Always       -       31 (Min/Max 24/31)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       3
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       11
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       167
194 Temperature_Celsius     0x0022   031   045   000    Old_age   Always       -       31 (0 21 0 0 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   099   099   000    Old_age   Offline      -       1395 (252 105 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       93180280
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       45691260
254 Free_Fall_Sensor        0x0032   100   100   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
 


le ssd sata3 sdb
commande


smartctl -a /dev/sdb
 


retour


smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.3.0-1-amd64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     CT240BX200SSD1
Serial Number:    1548F01207D0
LU WWN Device Id: 5 00a075 1f01207d0
Firmware Version: MU01.6
User Capacity:    240 057 409 536 bytes [240 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sat Feb 27 16:09:27 2016 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
          was never started.
          Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
          without error or no self-test has ever
          been run.
Total time to complete Offline
data collection:    (    0) seconds.
Offline data collection
capabilities:        (0x71) SMART execute Offline immediate.
          No Auto Offline data collection support.
          Suspend Offline collection upon new
          command.
          No Offline surface scan supported.
          Self-test supported.
          Conveyance Self-test supported.
          Selective Self-test supported.
SMART capabilities:            (0x0002) Does not save SMART data before
          entering power-saving mode.
          Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
          General Purpose Logging supported.
Short self-test routine
recommended polling time:    (   1) minutes.
Extended self-test routine
recommended polling time:    (   2) minutes.
Conveyance self-test routine
recommended polling time:    (   1) minutes.
SCT capabilities:          (0x0035) SCT Status supported.
          SCT Feature Control supported.
          SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0000   100   100   000    Old_age   Offline      -       0
  5 Reallocated_Sector_Ct   0x0000   100   100   000    Old_age   Offline      -       0
  9 Power_On_Hours          0x0000   100   100   000    Old_age   Offline      -       5
 12 Power_Cycle_Count       0x0000   100   100   000    Old_age   Offline      -       18
160 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       0
161 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       27
163 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       336
148 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       2357
149 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       51
150 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       2
151 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       35
164 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       1124
165 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       11
166 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       0
167 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       1
169 Unknown_Attribute       0x0000   100   100   001    Old_age   Offline      -       100
181 Program_Fail_Cnt_Total  0x0000   100   100   000    Old_age   Offline      -       0
182 Erase_Fail_Count_Total  0x0000   100   100   000    Old_age   Offline      -       0
192 Power-Off_Retract_Count 0x0000   100   100   000    Old_age   Offline      -       2
194 Temperature_Celsius     0x0000   100   100   070    Old_age   Offline      -       27 (37 34 34 35 0)
199 UDMA_CRC_Error_Count    0x0000   100   100   000    Old_age   Offline      -       0
232 Available_Reservd_Space 0x0000   100   100   000    Old_age   Offline      -       100
241 Total_LBAs_Written      0x0000   100   100   000    Old_age   Offline      -       3283
242 Total_LBAs_Read         0x0000   100   100   000    Old_age   Offline      -       1148
245 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       6638
246 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       4714
247 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       0

SMART Error Log Version: 1
No Errors Logged

Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
    6        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
 


le ssd M2  sda   (en PCIe )
commande


smartctl -a /dev/sda
 


retour


smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.3.0-1-amd64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     Crucial_CT250MX200SSD4
Serial Number:    15491131FE09
LU WWN Device Id: 5 00a075 11131fe09
Firmware Version: MU02
User Capacity:    250 059 350 016 bytes [250 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Form Factor:      < 1.8 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-3 T13/2161-D revision 4
SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sat Feb 27 16:10:28 2016 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
          was completed without error.
          Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
          without error or no self-test has ever
          been run.
Total time to complete Offline
data collection:    ( 4036) seconds.
Offline data collection
capabilities:        (0x7b) SMART execute Offline immediate.
          Auto Offline data collection on/off support.
          Suspend Offline collection upon new
          command.
          Offline surface scan supported.
          Self-test supported.
          Conveyance Self-test supported.
          Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
          power-saving mode.
          Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
          General Purpose Logging supported.
Short self-test routine
recommended polling time:    (   2) minutes.
Extended self-test routine
recommended polling time:    (   3) minutes.
Conveyance self-test routine
recommended polling time:    (   3) minutes.
SCT capabilities:          (0x0035) SCT Status supported.
          SCT Feature Control supported.
          SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   000    Pre-fail  Always       -       0
  5 Reallocated_Sector_Ct   0x0032   100   100   010    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       1371
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       36
171 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
173 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
174 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       16
180 Unused_Rsvd_Blk_Cnt_Tot 0x0033   000   000   000    Pre-fail  Always       -       2582
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0032   100   100   000    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   047   031   000    Old_age   Always       -       53 (Min/Max 29/69)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   100   100   000    Old_age   Always       -       0
202 Unknown_SSD_Attribute   0x0030   100   100   001    Old_age   Offline      -       0
206 Unknown_SSD_Attribute   0x000e   100   100   000    Old_age   Always       -       0
210 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
246 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       116917600
247 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       3654970
248 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       5015497

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Vendor (0xff)       Completed without error       00%      1367         -
# 2  Vendor (0xff)       Completed without error       00%      1326         -
# 3  Vendor (0xff)       Completed without error       00%      1291         -
# 4  Vendor (0xff)       Completed without error       00%      1250         -
# 5  Vendor (0xff)       Completed without error       00%      1209         -
# 6  Vendor (0xff)       Completed without error       00%      1168         -
# 7  Vendor (0xff)       Completed without error       00%      1122         -
# 8  Vendor (0xff)       Completed without error       00%      1101         -
# 9  Vendor (0xff)       Completed without error       00%      1048         -
#10  Vendor (0xff)       Completed without error       00%      1030         -
#11  Vendor (0xff)       Completed without error       00%       988         -
#12  Vendor (0xff)       Completed without error       00%       945         -
#13  Vendor (0xff)       Completed without error       00%       902         -
#14  Vendor (0xff)       Completed without error       00%       860         -
#15  Vendor (0xff)       Completed without error       00%       819         -
#16  Vendor (0xff)       Completed without error       00%       778         -
#17  Vendor (0xff)       Completed without error       00%       737         -
#18  Vendor (0xff)       Completed without error       00%       694         -
#19  Vendor (0xff)       Completed without error       00%       645         -
#20  Vendor (0xff)       Completed without error       00%       601         -
#21  Vendor (0xff)       Completed without error       00%       559         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Completed [00% left] (201291860-201357395)
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
 


j'ai récupéré ces informations a partir de debian sid (disque sdb)  , sda et sdc ne sont pas monté (font partie de l installation de debian stretch)


ps: pour en revenir aux disques 2.5 seagate j'ai monté un raid 10 materiel avec 8 disques de ce type pour archiver , et je ne pense pas que je puisse voir les disques individuellement
c'est une carte sata3 SAS Asus  8 sorties  (model PIKE 2008 lsisas raid card )

Dernière modification par anonyme (27-02-2016 17:26:30)

#54 27-02-2016 20:44:17

anonyme
Invité

Re : Vérifier vieux disque dur

encore une alerte , aurai -je bien fait d installer smartmontools ?  tongue  roll
un 40Go avec 55761 heures (soit 6.36 années de dur labeur )
sur le net j'ai trouvé 100 000 heures (11 années ) de MTBF pour les disques actuel , plus d un million pour ssd (intel)
j ai eu 51 erreurs (non fixé , le Reallocated_Sector_Ct est a 0  sad


=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model:     ST340014AS
Serial Number:    5MQ46MHD
Firmware Version: 3.00
User Capacity:    40 020 664 320 bytes [40,0 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA/ATAPI-6 T13/1410D revision 2
Local Time is:    Sat Feb 27 20:01:49 2016 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
          was completed without error.
          Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
          without error or no self-test has ever
          been run.
Total time to complete Offline
data collection:    (  430) seconds.
Offline data collection
capabilities:        (0x5b) SMART execute Offline immediate.
          Auto Offline data collection on/off support.
          Suspend Offline collection upon new
          command.
          Offline surface scan supported.
          Self-test supported.
          No Conveyance Self-test supported.
          Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
          power-saving mode.
          Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
          No General Purpose Logging support.
Short self-test routine
recommended polling time:    (   1) minutes.
Extended self-test routine
recommended polling time:    (  24) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   051   046   006    Pre-fail  Always       -       187203115
  3 Spin_Up_Time            0x0003   098   098   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   091   091   020    Old_age   Always       -       9543
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   090   060   030    Pre-fail  Always       -       986767420
  9 Power_On_Hours          0x0032   037   037   000    Old_age   Always       -       55716
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   099   020    Old_age   Always       -       2005
194 Temperature_Celsius     0x0022   038   048   000    Old_age   Always       -       38 (0 14 0 0 0)
195 Hardware_ECC_Recovered  0x001a   051   046   000    Old_age   Always       -       187203115
197 Current_Pending_Sector  0x0012   098   097   000    Old_age   Always       -       51
198 Offline_Uncorrectable   0x0010   098   097   000    Old_age   Offline      -       51
199 UDMA_CRC_Error_Count    0x003e   200   199   000    Old_age   Always       -       1
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 Data_Address_Mark_Errs  0x0032   100   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 142 (device log contains only the most recent five errors)
  CR = Command Register [HEX]
  FR = Features Register [HEX]
  SC = Sector Count Register [HEX]
  SN = Sector Number Register [HEX]
  CL = Cylinder Low Register [HEX]
  CH = Cylinder High Register [HEX]
  DH = Device/Head Register [HEX]
  DC = Device Command Register [HEX]
  ER = Error register [HEX]
  ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 142 occurred at disk power-on lifetime: 54000 hours (2250 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 d4 f4 f5 04 e2  Error: UNC 212 sectors at LBA = 0x0204f5f4 = 33879540

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 00 20 f5 04 e2 00      00:01:00.612  READ DMA
  c8 00 08 98 f4 04 e2 00      00:01:00.612  READ DMA
  c8 00 08 88 f4 04 e2 00      00:01:00.604  READ DMA
  c8 00 08 80 f4 04 e2 00      00:01:00.596  READ DMA
  c8 00 08 68 f4 04 e2 00      00:01:00.596  READ DMA

Error 141 occurred at disk power-on lifetime: 54000 hours (2250 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 5f bf f4 04 e2  Error: UNC 95 sectors at LBA = 0x0204f4bf = 33879231

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 c0 60 f4 04 e2 00      00:00:56.819  READ DMA
  c8 00 20 40 f4 04 e2 00      00:00:56.819  READ DMA
  c8 00 08 38 f4 04 e2 00      00:00:56.819  READ DMA
  c8 00 20 08 f4 04 e2 00      00:00:56.819  READ DMA
  c8 00 08 00 f4 04 e2 00      00:00:56.819  READ DMA

Error 140 occurred at disk power-on lifetime: 54000 hours (2250 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 74 5c f3 04 e2  Error: UNC 116 sectors at LBA = 0x0204f35c = 33878876

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 c0 e8 f2 04 e2 00      00:00:52.961  READ DMA
  c8 00 20 c8 f2 04 e2 00      00:00:52.961  READ DMA
  c8 00 08 c0 f2 04 e2 00      00:00:52.951  READ DMA
  c8 00 20 48 f2 04 e2 00      00:00:52.951  READ DMA
  c8 00 08 40 f2 04 e2 00      00:00:52.950  READ DMA

Error 139 occurred at disk power-on lifetime: 54000 hours (2250 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 5f bf f4 04 e2  Error: UNC 95 sectors at LBA = 0x0204f4bf = 33879231

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 c0 60 f4 04 e2 00      00:00:26.598  READ DMA
  c8 00 20 40 f4 04 e2 00      00:00:26.597  READ DMA
  c8 00 08 38 f4 04 e2 00      00:00:26.597  READ DMA
  c8 00 20 08 f4 04 e2 00      00:00:26.597  READ DMA
  c8 00 08 00 f4 04 e2 00      00:00:26.597  READ DMA

Error 138 occurred at disk power-on lifetime: 54000 hours (2250 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 74 5c f3 04 e2  Error: UNC 116 sectors at LBA = 0x0204f35c = 33878876

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 c0 e8 f2 04 e2 00      00:00:22.785  READ DMA
  c8 00 20 c8 f2 04 e2 00      00:00:22.784  READ DMA
  c8 00 08 c0 f2 04 e2 00      00:00:22.784  READ DMA
  c8 00 20 48 f2 04 e2 00      00:00:22.790  READ DMA
  c8 00 08 40 f2 04 e2 00      00:00:22.790  READ DMA

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
 


faut t il se séparer de ce disque hmm
ps: je vai essayer de faire une copy bootable du disque ( et tenter une récupération histoire de rester joueur cool )

#55 01-03-2016 14:01:15

anonyme
Invité

Re : Vérifier vieux disque dur

Aprés avoir fait une copie du disque en #54 ,  je suis en train de faire  un :


badblocks -s -v -w /dev/sdb
 



Vérification des blocs défectueux en mode lecture-écriture
Du bloc 0 au bloc 39082679
Test en cours avec le motif 0xaa: complété                                            
Lecture et comparaison :
 


par curiosité voir si il arrive a récupérer les 51 soucis

il a récupéré un secteur
comme smartd m 'envoie des mails régulierement , le disques est irrécupérable (meme si il fonctionne sans soucis )
ceci est important et je pense qu il vaut mieux que ça reste a 0


197 Current_Pending_Sector  0x0012   098   097   000    Old_age   Always       -       51
198 Offline_Uncorrectable   0x0010   098   097   000    Old_age   Offline      -       51
 


les valeurs sont passées a 50 , je refais une Vérification des blocs défectueux sans conviction  hmm
le retour du premier test


Vérification des blocs défectueux en mode lecture-écriture
Du bloc 0 au bloc 39082679
Test en cours avec le motif 0xaa: complété                                            
Lecture et comparaison : complété                                            
Test en cours avec le motif 0x55: complété                                            
Lecture et comparaison : complété                                            
Test en cours avec le motif 0xff: complété                                            
Lecture et comparaison : complété                                            
Test en cours avec le motif 0x00: complété                                            
Lecture et comparaison : complété                                            
Passe complétée, 0 blocs défectueux repérés. (0/0/0 erreurs)
 

Dernière modification par anonyme (01-03-2016 15:42:45)