Bonjour,
J'ai installé dernièrement Debian 10 Gnome 64 bits à une amie, sur un X302LJ (ASUS-NotebookSKU)
Il tourne bien, j'ai juste un doute sur l'état de santé du disque dur ( voir infos ci-dessous)
Au cas où il faudrait le changer, j'ai un doute que cela puisse se faire, car la seule trappe qu'on peut ouvrir sous l'ordi c'est pour rajouter de la RAM.
Qu'en pensez-vous ? merci d'avance.
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-9-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Toshiba 2.5" HDD MQ01ABD...
Device Model: TOSHIBA MQ01ABD100
Serial Number: 956VTUWZT
LU WWN Device Id: 5 000039 681f02483
Firmware Version: AX0R2J
User Capacity: 1000204886016 bytes [1,00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Jun 4 15:54:48 2020 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF ENABLE/DISABLE COMMANDS SECTION ===
SMART Enabled.
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 246) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1693
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 5723
5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7429
10 Spin_Retry_Count 0x0033 213 100 030 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 5723
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 14017
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 33
193 Load_Cycle_Count 0x0032 096 096 000 Old_age Always - 47496
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 31 (Min/Max 9/55)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 1408
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 176
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
220 Disk_Shift 0x0002 100 100 000 Old_age Always - 0
222 Loaded_Hours 0x0032 084 084 000 Old_age Always - 6561
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0
224 Load_Friction 0x0022 100 100 000 Old_age Always - 0
226 Load-in_Time 0x0026 100 100 000 Old_age Always - 269
240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0
SMART Error Log Version: 1
ATA Error Count: 32487 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 32487 occurred at disk power-on lifetime: 7210 hours (300 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 f8 40 53 36 40 Error: UNC at LBA = 0x00365340 = 3560256
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 00 78 94 07 40 00 06:17:55.787 READ FPDMA QUEUED
60 08 f8 40 53 36 40 00 06:17:55.444 READ FPDMA QUEUED
61 08 f0 f8 5c 68 40 00 06:17:55.444 WRITE FPDMA QUEUED
60 03 e8 a2 3e 7c 40 00 06:17:55.434 READ FPDMA QUEUED
60 08 e0 40 27 ac 40 00 06:17:55.413 READ FPDMA QUEUED
Error 32486 occurred at disk power-on lifetime: 7210 hours (300 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 08 40 53 36 40 Error: UNC at LBA = 0x00365340 = 3560256
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 a0 78 d3 33 40 00 06:17:51.260 READ FPDMA QUEUED
61 18 98 f8 1c 50 40 00 06:17:51.235 WRITE FPDMA QUEUED
60 08 90 7a 97 e5 40 00 06:17:51.201 READ FPDMA QUEUED
60 08 88 63 f7 cb 40 00 06:17:51.184 READ FPDMA QUEUED
60 08 80 f8 35 20 40 00 06:17:51.181 READ FPDMA QUEUED
Error 32485 occurred at disk power-on lifetime: 7210 hours (300 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 f8 40 53 36 40 Error: UNC at LBA = 0x00365340 = 3560256
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 40 00 d2 d3 34 40 00 06:17:47.037 READ FPDMA QUEUED
60 08 f8 40 53 36 40 00 06:17:47.015 READ FPDMA QUEUED
60 08 f0 d0 8e 0d 40 00 06:17:47.005 READ FPDMA QUEUED
60 08 e8 c2 9c 17 40 00 06:17:46.994 READ FPDMA QUEUED
61 08 e0 90 64 11 40 00 06:17:46.994 WRITE FPDMA QUEUED
Error 32484 occurred at disk power-on lifetime: 7210 hours (300 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 68 40 53 36 40 Error: UNC at LBA = 0x00365340 = 3560256
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 12 a0 28 07 b1 40 00 06:17:43.110 READ FPDMA QUEUED
60 40 98 db 5f cc 40 00 06:17:42.995 READ FPDMA QUEUED
60 10 90 20 2a 20 40 00 06:17:42.991 READ FPDMA QUEUED
60 20 88 d6 17 cd 40 00 06:17:42.984 READ FPDMA QUEUED
60 40 78 e2 07 e0 40 00 06:17:42.977 READ FPDMA QUEUED
Error 32483 occurred at disk power-on lifetime: 7210 hours (300 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 78 40 53 36 40 Error: UNC at LBA = 0x00365340 = 3560256
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 18 30 08 4b 07 40 00 06:17:38.777 READ FPDMA QUEUED
61 00 28 e8 a7 ba 40 00 06:17:38.776 WRITE FPDMA QUEUED
61 00 20 e8 a6 ba 40 00 06:17:38.776 WRITE FPDMA QUEUED
61 10 18 c0 4b 64 40 00 06:17:38.776 WRITE FPDMA QUEUED
61 00 10 e8 a5 ba 40 00 06:17:38.776 WRITE FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 00% 7265 633947712
# 2 Extended offline Interrupted (host reset) 60% 7214 -
# 3 Short offline Completed without error 00% 7210 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Dernière modification par le_lutin (21-09-2020 10:35:34)